Series Available

Cylindrical

 • Amphenol 97 (Solder)

 • Amphenol 97 (Crimp)

 • Amphenol 97E (Env.)

 • Amphenol JT

 • Amphenol LJT

 • Amphenol TV

 • M5015 Solder

 • M5015 Crimp

 • M22992 Class L

 • M22992 Series QWLD

 • M26482 Series I

 • M26482 Series II

 • M26500

 • M27599 (Solder)

 • M28840

 • D38999 Series I

 • D38999 Series II

 • D38999 Series III

 • D38999 Series III RJ45

 • D38999 Series III USB

 • M81511 Series I & II

 • M83723 Series III

 • 80 Series Mighty Mouse

Rack & Panel

 • M55302

RF

 • M39012

 • View Catalog

Micro D-Sub

 • M83513

Backshell

 • M85049

Contacts & Termini

 • M39029

 • Coax, Twinax, Triax

 • M29504 Termini

Circuit Protection

 • Raychem PolySwitch

Tooling

 • Crimp Tools

Need Help Finding It?

If you don't know what the manufacturer's part number is, contact us.

We are happy to be of assistance to you.

SMB Series RF Connectors

SMB Connector

RF Connectors > SMB Series RF Connectors

Description

The SMB name derives from SubMiniature B (the second subminiature design). Developed in the 1960’s, the SMB is a smaller version of the SMA with snap-on coupling. Amphenol’s SMB connectors conform to the requirements of MIL-C-39012, and the interface is in compliance with MIL-STD-348. Available in 50 Ω and 75 Ω impedance, the SMB provides broadband capability through 4 GHz with a snap-on connector design and utilizes die cast components on non-critical areas to provide a low-cost solution.

Features & Benefits

  • Broadband performance with low reflection DC to 4 GHz provides low cost connector combined with high quality.
  • Quick connect/disconnect snap-on mating reduces installation time.
  • Various plating options in nickel, gold, and tin lead. Selective plating provides corrosion resistance finish as well as good solderability characteristics.
  • SMB PCB slide-on plug and jack allows board-to-board mounting with a low insertion force. This is ideal for mating a high number of connectors on a pair of PCB’s.

Applications

  • Automotive
  • Automotive (GPS)
  • Base Stations
  • Cable Assemblies
  • Components
  • Instrumentation
  • PC/LAN
  • Process Controls
  • Radio Boards
  • Surge Protection
  • Telecom
  • Test & Measurement
  • Video Systems
50 Ω SMB Specifications
Impedance 50 Ω
Frequency Range 0-4 GHz with low reflection; usable to 10.0 GHz
Voltage Rating for RG-188/U Cable 335 volts at sea level and 85 volts at 70,000 feet
Dielectric Withstanding Voltage RG-196: 750 VRMS; RG-188: 1,000 VRMS
VSWR Straight connector, RG-196/U: 1.30 + .04 f (GHz)
Right angle connector, RG-196/U: 1.45 + .06 f (GHz)
Straight connector, RG-188/U: 1.25 + .04 f (GHz)
Right angle connector, RG-188/U: 1.35 + .04 f (GHz)
Contact Resistance Center contact: 6.0 mΩ initial, 8.0 after environmental;
Outer contact: 1.0 mΩ initial, 1.5 after environmental
Braid to body: 1.0 mΩ initial, after environmental N/A
Insulation Resistance 1,000 MΩ minimum
Insertion Loss Straight connector: 0.30 dB @ 1.5 GHz
Right angle connector: 0.60 dB @ 1.5 GHz
RF Leakage -55 dB minimum @ 2-3 GHz
Mating Snap-on coupling per MIL-STD-348
Braid/Jacket Cable Affixment Hex crimp
Center Conductor Cable Affixment Solder
Contact Captivation All types unless noted otherwise
Cable Retention Equal to breaking strength of cable employed
Engagement Forces Engagement: 14 lbs maximum
Disengagement: 2 lbs minimum
After 500 matings, 14 lbs maximum engagement and disengagement
Connector Durability 500 mating cycles minimum
Center Contact Female: beryllium copper, gold-plated
Male: brass or beryllium copper, gold-plated
Outer Contact Plating Nickel or gold plating as indicated
Body Brass per QQB-626, or zinc per ASTM B86-71
Body Plating Nickel or gold plating as indicated
Insulator TFE
Crimp Ferrule Annealed copper alloy
Temperature Range - 65°C to +165°C
Thermal Shock MIL-STD-202 method 107, test condition B (except high temperatures
@ 200°C
Shock MIL-STD-202 method 202, method 13, snap-on, test condition
B; 75 G’s @ 6 milliseconds ½ sine
Vibration MIL-STD-202 method 204, snap-on, test condition B; (15 G’s)
Corrosion MIL-STD-202 method 101, test condition B. 5% salt solution
75 Ω SMB Specifications
Impedance 75 Ω
Frequency Range 0-4 GHz with low reflection; usable to 10.0 GHz
Voltage Rating for RG-188/U Cable 335 volts at sea level and 85 volts at 70,000 feet
Dielectric Withstanding Voltage 1,000 VRMS
RF High Potential Withstanding Voltage RF-195/U series: 500 VRMS
Corona Level RG-195/U series: 400 volts minimum @ 70,000 ft
VSWR Straight connector, RG-196/U: 1.30 + .04 f (GHz)
Right angle connector, RG-196/U: 1.45 + .06 f (GHz)
Straight connector, RG-188/U: 1.25 + .04 f (GHz)
Right angle connector, RG-188/U: 1.35 + .04 f (GHz)
Contact Resistance Center contact: 6.0 mΩ initial, 8.0 after environmental;
Outer contact: 1.0 mΩ initial, 1.5 after environmental
Braid to body: 1.0 mΩ initial, after environmental N/A
Insulation Resistance 1,000 MΩ minimum
Insertion Loss Straight connector: 0.30 dB @ 1.5 GHz
Right angle connector: 0.60 dB @ 1.5 GHz
RF Leakage -55 dB minimum @ 2-3 GHz
Mating Snap-on coupling per MIL-STD-348
Braid/Jacket Cable Affixment Hex crimp
Center Conductor Cable Affixment Solder
Contact Captivation All types unless noted otherwise
Cable Retention Equal to breaking strength of cable employed
Engagement Forces Engagement: 14 lbs maximum
Disengagement: 2 lbs minimum
After 500 matings, 14 lbs maximum engagement and disengagement
Connector Durability 500 mating cycles minimum
Center Contact Female: beryllium copper, gold-plated
Male: brass or beryllium copper, gold-plated
Outer Contact Plating Nickel or gold plating as indicated
Body Brass per QQB-626
Body Plating Nickel or gold plating as indicated
Insulator TFE
Crimp Ferrule Annealed copper alloy
Temperature Range - 65°C to +165°C
Thermal Shock MIL-STD-202 method 107, test condition B (except high temperatures @ 200°C
Shock MIL-STD-202 method 213, snap-on, test condition B; 75 G’s @ 6 milliseconds ½ sine
Vibration MIL-STD-202 method 202, snap-on, test condition B; (15 G’s)
Corrosion MIL-STD-202 method 101, test condition B. 5% salt solution
75 Ω High Density SMB Specifications
Impedance 75 Ω
Frequency Range 0-4 GHz with low reflection; usable to 10.0 GHz
Voltage Rating for RG-188/U Cable 335 volts at sea level and 85 volts at 70,000 feet
Dielectric Withstanding Voltage RG-196: 750 VRMS
RG-188: 1,000 VRMS
VSWR Straight connector, 735A: 1.25 + .04 f (GHz)
Right angle connector, 735A: 1.35 + .04 f (GHz)
Contact Resistance Center contact: 6.0 mΩ initial, 8.0 after environmental;
Outer contact: 1.0 mΩ initial, 1.5 after environmental
Braid to body: 1.0 mΩ initial, after environmental N/A
Insulation Resistance 1,000 MΩ minimum
Insertion Loss Straight connector: 0.30 dB @ 1.5 GHz
Right angle connector: 0.60 dB @ 1.5 GHz
RF Leakage -55 dB minimum @ 2-3 GHz
Mating Snap-on coupling per MIL-STD-348
Braid/Jacket Cable Affixment Hex crimp
Center Conductor Cable Affixment Solder or crimp
Contact Captivation All types unless noted otherwise
Cable Retention Equal to breaking strength of cable employed Engagement Forces
Engagement Forces Engagement: 14 lbs maximum
Disengagement: 2 lbs minimum
After 500 matings, 14 lbs maximum engagement and disengagement
Connector Durability 500 mating cycles minimum
Center Contact Female: beryllium copper, gold-plated
Male: brass or beryllium copper, gold-plated
Outer Contact Plating Nickel or gold plating as indicated
Body Brass per QQB-626
Body Plating Nickel or gold plating as indicated
Insulator TFE
Crimp Ferrule Annealed copper alloy
Temperature Range - 65°C to +165°C
Thermal Shock MIL-STD-202 method 107, test condition B (except high temperatures @ 200°C
Shock MIL-STD-202 method 213, snap-on, test condition B; 75 G’s @ 6 milliseconds ½ sine
Vibration MIL-STD-202 method 202, snap-on, test condition B; (15 G’s)
Corrosion MIL-STD-202 method 101, test condition B. 5% salt solution